EM-7 Multi-Parameter Monitor




 
 
  EM-7 Multi-Parameter Monitor

  Specification
 
Use Built-In System, High Integrated Intelligent Module Technology, Full DigitalMonitoring, Super Function, and Lowest Wearing, Low Failure Rate.
12.1″TFT High Resolving Power Colored Display, Selective English and Chinese.
7leads ECG/SPO2/RESP/9 Waves Displaying on The Same Screen.
ST Segment Analysis, 20 Kinds Wrong HR Analysis.
ECG Wave Saving and Replaying Function. Be Used When Power Is Off.
120 Hours Measuring Chart Display.
600 Groups NIBP Date Storage.
Direct, Reverse and Quick Three Measuring Modes, Be Suit to Adult/ Children/Neonate.
Protecting Function for the NIBP Over Range.
Defibrillation, Anti the Interference of High-Frequency Electro Tome.
Compatible with Central Monitoring System, Buildup the Central
Monitoring System.
Selective Build-in Thermal Printer
Optional Equipment: Double Access IBP, Eed Tidal CO2.
 
Six Technical Parameters
 
Operating: Temperature +5℃~+5℃ Humidity≤80%
Storage: Temperature -20℃~+55℃ Humidity≤93%
Battery: Built-in Rechargeable Battery; Maximum Utility Time≥2 Hours
 
ECG
Displaying Graphics Of 7 Lead On The Same Screen.
Overload Protection: Defibrillation. Anti the Interference of High-Frequency Electrolome.
Lead: 5 Lead (RA, LA, RL, LL, and C)
Lead Selection: I; Ⅱ; Ⅲ; Avr; Avl; Avf; V.
Waveform: ≤9 Channels
Gain Selection: ×0.5;×1;×2;×4
Electrical Leakage: <30μA
Baseline Recovery Time: <3 sec. Following Defibrillation
Protection: Separates and Withstands 4000V AC/50Hz Defibrillation, Resistant to Interference of Electrotonus And Myoelectricity.
Scan Speed:12.5mm/sec; 25mm/sec; 50mm/sec
Lead Drop: Auto Detection
Modes: DIA: 0.05~75Hz,MON: 0.5~35Hz, OPE: 1~25Hz
HR
Measurement Range: 0~254bpm
Accuracy: ±1bpm Or ±2%
Resolution: 1bpm
ECG Calibration: 1mV (Peak Value)
ST Segment Offset (Diagnose Mode)
Measurement Range:-1.0mV~+ -1.0mV
Accuracy: ±0.02mV or ±5%

RESP

Model: RA-LL Impedance
Measurement/Alarm Range: 1-99rpm
Resolution: 1rpm
Accuracy:±2rpm
TEMP

Measurement Range:25℃~45℃
Resolution:0.1℃
Accuracy:±0.2℃
Average Measurement Time: <10sec
Alarm: Sound, Light

NIBP
Unique Direct, Reverse and Quick Modes
Method: Automatic Oscillometric
Working Mode: Auto/Manual
Interval of Auto Mode: 1-60 Min
Measurement Unit: mmHg/kPa Selectable
Measurement Ranges: Systolic BP; Diastolic BP and Mean BP
Applicability: Adult/Pediatric/Neonatal
Overload Protection: Dual Security Protection

SPO2
SPO2 Probe of High Intensity and Durability
Excellent Measurement of Low Perfusion
Anti Interference of Movement
Measurement Range:0~100%
Alarm Range: 0~100%
Resolution: ±1%
Accuracy: ±2%(80-100%)
                   ±3%(60-79%)
PR Range:0~254bpm

 

 