▲Specification |
| |
●Use
Built-In System, High Integrated Intelligent Module
Technology, Full DigitalMonitoring, Super Function,
and Lowest Wearing, Low Failure Rate.
●12.1″TFT
High Resolving Power Colored Display, Selective
English and Chinese.
●7leads
ECG/SPO2/RESP/9 Waves Displaying on The Same Screen.
●ST
Segment Analysis, 20 Kinds Wrong HR Analysis.
●ECG
Wave Saving and Replaying Function. Be Used When
Power Is Off.
●120
Hours Measuring Chart Display.
●600
Groups NIBP Date Storage.
●Direct,
Reverse and Quick Three Measuring Modes, Be Suit to
Adult/ Children/Neonate.
●Protecting
Function for the NIBP Over Range.
●Defibrillation,
Anti the Interference of High-Frequency Electro
Tome.
●Compatible
with Central Monitoring System, Buildup the Central
●Monitoring
System.
●Selective
Build-in Thermal Printer
●Optional
Equipment: Double Access IBP, Eed Tidal CO2. |
|
|
|
▲Six
Technical Parameters |
|
|
●Operating:
Temperature +5℃~+5℃ Humidity≤80%
●Storage:
Temperature -20℃~+55℃ Humidity≤93%
●Battery:
Built-in Rechargeable Battery; Maximum Utility
Time≥2 Hours |
| |
| ▲ECG |
|
|
●Displaying
Graphics Of 7 Lead On The Same Screen.
●Overload
Protection: Defibrillation. Anti the Interference of
High-Frequency Electrolome.
●Lead:
5 Lead (RA, LA, RL, LL, and C)
●Lead
Selection: I; Ⅱ; Ⅲ; Avr; Avl; Avf; V.
●Waveform:
≤9 Channels
●Gain
Selection: ×0.5;×1;×2;×4
●Electrical
Leakage: <30μA
●Baseline
Recovery Time: <3 sec. Following Defibrillation
●Protection:
Separates and Withstands 4000V AC/50Hz
Defibrillation, Resistant to
Interference
of Electrotonus And Myoelectricity.
●Scan
Speed:12.5mm/sec; 25mm/sec; 50mm/sec
●Lead
Drop: Auto Detection
●Modes:
DIA: 0.05~75Hz,MON: 0.5~35Hz, OPE: 1~25Hz |
|
|
|
▲HR |
|
|
●Measurement
Range: 0~254bpm
●Accuracy:
±1bpm Or ±2%
●Resolution:
1bpm
●ECG
Calibration: 1mV (Peak Value)
●ST
Segment Offset (Diagnose Mode)
●Measurement
Range:-1.0mV~+ -1.0mV
●Accuracy:
±0.02mV or ±5% |
|
|
|
▲RESP |
|
|
●Model:
RA-LL Impedance
●Measurement/Alarm
Range: 1-99rpm
●Resolution:
1rpm
●Accuracy:±2rpm |
|
|
|
▲TEMP |
|
|
|
●Measurement
Range:25℃~45℃
●Resolution:0.1℃
●Accuracy:±0.2℃
●Average
Measurement Time: <10sec
●Alarm:
Sound, Light |
|
|
|
▲NIBP |
|
|
●Unique
Direct, Reverse and Quick Modes
●Method:
Automatic Oscillometric
●Working
Mode: Auto/Manual
●Interval
of Auto Mode: 1-60 Min
●Measurement
Unit: mmHg/kPa Selectable
●Measurement
Ranges: Systolic BP; Diastolic BP and Mean BP
●Applicability:
Adult/Pediatric/Neonatal
●Overload
Protection: Dual Security Protection |
|
|
|
▲SPO2 |
|
|
●SPO2
Probe of High Intensity and Durability
●Excellent
Measurement of Low Perfusion
●Anti
Interference of Movement
●Measurement
Range:0~100%
●Alarm
Range: 0~100%
●Resolution:
±1%
●Accuracy:
±2%(80-100%)
±3%(60-79%)
●PR
Range:0~254bpm |
|
|