BEIJING HONGRUNDA SCI-TECH DEVELOPMENT CO., LTD
 PRODUCT   LIST
PRODUCTS
Patient Monitor
Name:Patient Monitor
Model:EM-7
Information:
 
●Use Built-In System, High Integrated Intelligent Module Technology, Full DigitalMonitoring, Super Function, and Lowest Wearing, Low Failure Rate.
●12.1″TFT High Resolving Power Colored Display, Selective English and Chinese.
●7leads ECG/SPO2/RESP/multi- Waves Displaying on The Same Screen.
●ST Segment Analysis, 20 Kinds Wrong HR Analysis.
●ECG Wave Saving and Replaying Function. Be Used When Power Is Off.
●120 Hours Measuring Chart Display.
●600 Groups NIBP Date Storage.
●Direct, Reverse and Quick Three Measuring Modes, Be Suit to Adult/ Children/Neonate.
●Protecting Function for the NIBP Over Range.
●Defibrillation, Anti the Interference of High-Frequency Electro Tome.
●Compatible with Central Monitoring System, Buildup the Central
●Monitoring System.
●Selective Build-in Thermal Printer
●Optional Equipment: Double Access IBP, Eed Tidal CO2.
 
▲Six Technical Parameters
 
●Operating: Temperature +5℃~+5℃ Humidity≤80%
●Storage: Temperature -20℃~+55℃ Humidity≤93%
●Battery: Built-in Rechargeable Battery; Maximum Utility Time≥2 Hours
 
▲ECG
 
●Displaying Graphics Of multi- Lead On The Same Screen.
●Overload Protection: Defibrillation. Anti the Interference of High-Frequency Electrolome.
●Lead: 5 Lead (RA, LA, RL, LL, and C)
●Lead Selection: I; Ⅱ; Ⅲ; Avr; Avl; Avf; V.
●Waveform: ≤9 Channels
●Gain Selection: ×0.5;×1;×2;×4
●Electrical Leakage: <30μA
●Baseline Recovery Time: <3 sec. Following Defibrillation
●Protection: Separates and Withstands 4000V AC/50Hz Defibrillation, Resistant to Interference of Electrotonus And Myoelectricity.
●Scan Speed:12.5mm/sec; 25mm/sec; 50mm/sec
●Lead Drop: Auto Detection
●Modes: DIA: 0.05~75Hz,MON: 0.5~35Hz, OPE: 1~25Hz
 
▲HR
 
●Measurement Range: 0~254bpm
●Accuracy: ±1bpm Or ±2%
●Resolution: 1bpm
●ECG Calibration: 1mV (Peak Value)
●ST Segment Offset (Diagnose Mode)
●Measurement Range:-1.0mV~+ -1.0mV
●Accuracy: ±0.02mV or ±5%
 
▲RESP
 
 
●Model: RA-LL Impedance
●Measurement/Alarm Range: 1-99rpm
●Resolution: 1rpm
●Accuracy:±2rpm
 
▲TEMP
 
●Measurement Range:25℃~45℃
●Resolution:0.1℃
●Accuracy:±0.2℃
●Average Measurement Time: <10sec
●Alarm: Sound, Light
 
 
▲NIBP
 
●Unique Direct, Reverse and Quick Modes
●Method: Automatic Oscillometric
●Working Mode: Auto/Manual
●Interval of Auto Mode: 1-60 Min
●Measurement Unit: mmHg/kPa Selectable
●Measurement Ranges: Systolic BP; Diastolic BP and Mean BP
●Applicability: Adult/Pediatric/Neonatal
●Overload Protection: Dual Security Protection
 
 
▲SPO2
 
●SPO2 Probe of High Intensity and Durability
●Excellent Measurement of Low Perfusion
●Anti Interference of Movement
●Measurement Range:0~100%
●Alarm Range: 0~100%
●Resolution: ±1%
●Accuracy: ±2%(80-100%)
                   ±3%(60-79%)
●PR Range:0~254bpm
 
Pakage Size: 575x450x595mm Gross Weight: 15KGS
Address:No.4,Zheng Da Nan Road,Beijing, P.R.C Zip Code:100039
Fax:+86 10 68233313 Tel:+86 10 68229643 E-mail:bjhrd@bjhrd.com.cn